| Title: | Estimativa da taxa de renovação do ar e do número de ocupantes a partir da concentração de CO₂ em ambientes com diferentes padrões de ocupação |
| Author: | Lütchemeyer, Rafael da Rosa |
| First advisor: | Cassol, Fabiano |
| metadata.dc.contributor.referee1: | Carotenuto, Adriano Roberto da Silva |
| metadata.dc.contributor.referee2: | Feliciano, Manuel Joaquim Sabença |
| Resume: | A qualidade do ar interior é um fator fundamental para a saúde, o conforto e o bem-estar dos ocupantes, uma vez que concentrações elevadas de contaminantes podem estar associadas a sintomas como sonolência, fadiga, dores de cabeça e redução do desempenho cognitivo. Dessa forma, o dióxido de carbono (CO2), gerado principalmente pela respiração humana, é amplamente utilizado como indicador da eficiência da ventilação e da renovação do ar em ambientes fechados. Para isso, foram selecionados um auditório universitário, caracterizado por elevadas concentrações de pessoas em curtos períodos de tempo, e um supermercado local, que apresenta fluxo contínuo e alta circulação de clientes e funcionários ao longo do dia. As medições foram realizadas por meio do equipamento Testo 160 IAQ, capaz de registrar continuamente as concentrações de CO2. Os dados foram coletados durante períodos consecutivos, com registros em intervalos de um minuto. O objetivo do monitoramento foi o de determinar os limites de concentração de CO2 no ambiente, estimar a taxa de renovação do ar com e sem ocupação, e o número de ocupantes do ambiente. Para o auditório universitário, a concentração máxima de CO2 identificada foi de 2759 ppm e a taxa de renovação do ar identificada foi de 0,08 h-1. Para o supermercado, a concentração máxima de CO2 identificada foi de 1455 ppm e a melhor taxa de renovação do ar foi de 0,60 h-1. As normativas técnicas como a Resolução RE nº 9/2003 da ANVISA e a Organização Mundial da Saúde estabelecem um limite de 1000 ppm na concentração de CO2, como também a ABNT NBR 17037:2023 determina um limite de aproximadamente 1180 ppm, correspondente à concentração externa acrescida de 700 ppm. Isso indica a necessidade do planejamento de um sistema de ventilação mecânica, para manter a qualidade do ar de acordo com os parâmetros necessários para o bem estar dos ocupantes. |
| Abstract: | Indoor air quality is a key factor for the health, comfort, and well‑being of occupants, as high concentrations of contaminants can be associated with symptoms such as drowsiness, fatigue, headaches, and reduced cognitive performance. Accordingly, carbon dioxide (CO₂), produced mainly by human respiration, is widely used as an indicator of ventilation efficiency and air renewal in enclosed spaces. For this study, two locations were selected: a university auditorium, characterized by high occupancy levels over short periods, and a local supermarket, which presents a continuous flow and high turnover of customers and employees throughout the day. Measurements were carried out using the Testo 160 IAQ device, which enables continuous recording of CO₂ concentrations. Data were collected over consecutive periods, with readings taken at one‑minute intervals. The objective of this monitoring was to determine CO₂ concentration levels in the environments, estimate the air exchange rate under occupied and unoccupied conditions, and assess the number of occupants. For the university auditorium, the maximum CO₂ concentration recorded was 2,759 ppm, with an air exchange rate of 0.08 h⁻¹. For the supermarket, the maximum CO₂ concentration reached 1,455 ppm, and the best air exchange rate obtained was 0.60 h⁻¹. Technical standards such as ANVISA Resolution RE No. 9/2003 and guidelines from the World Health Organization establish a limit of 1,000 ppm for CO₂ concentration; similarly, Brazilian standard ABNT NBR 17037:2023 sets a limit of approximately 1,180 ppm, corresponding to the outdoor concentration plus an increment of 700 ppm. These findings indicate the need to plan and implement a mechanical ventilation system in order to maintain air quality in compliance with the parameters required for the well‑being of the occupants. |
| Keywords: | Qualidade do ar Dióxido de carbono Contaminação do ar |
| Language: | por |
| Country: | Brasil |
| Publisher: | Universidade Federal da Fronteira Sul |
| Acronym of the institution: | UFFS |
| College, Institute or Department: | Campus Cerro Largo |
| Type of Access: | Acesso Embargado |
| URI: | https://rd.uffs.edu.br/handle/prefix/9822 |
| Issue Date: | 29-Jun-2026 |
| Appears in Collections: | Engenharia Ambiental |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| LÜTCHEMEYER.pdf | 3.47 MB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.